Fire Equipment

Warehouse sprinkler


       Warehouse sprinklers are designed for special applications such as high level water storage systems. This type of sprinkler provides more water under low pressure. If the user has the correct pressure adjustment for the ESFR sprinkler, there is no need to use any other sprinklers between the ladders.
        This type of sprinkler is designed to prevent the ladder from breaking. When using, users should pay attention to their characteristics. The waterproof cover is very important for heat detection. If the water hood is not used in the sprinkler system, the sprinkler will not reach the required heat and will not start.
 
Application range
        warehouse
        the mall
        Stack storage
        Logistics
Warehouse sprinklers include 4 types
        - ESFR (early suppression fast response) sprinkler
        - CMSA (Control Mode Specific Application) Sprinkler
        - CMDA (Control Mode Density Zone) sprinkler
        - EC storage (extended coverage) sprinkler


 
ESFR (early suppression fast response) sprinkler
ESFR has three differences compared to other sprinklers:
Speed - ESFR sprinklers have twice the heat detection and start-up time than other sprinklers;
Spray volume - other sprinklers can spray water 25-60 gpm, while ESFR can spray water 100 gpm;
Water Drop Size - ESFR has large water droplets and flow rates compared to other sprinklers.

 
Upright type
Connection diameter: 3⁄4" npt
Assembly type: upright type
K factor: 14 (200)
Certification: FM, UL, ULC, LPCB, VdS
Temperature: 74 ° C, 96 ° C
Surface: brass
Product Name: VK520
- ESFR (early suppression, fast response) in fire mode
- Use solder to withstand heat
- Protective shelf system
- Suitable for racking systems
- Can replace the drooping connection

 
ESFR – K: 17 (242) sprinkler
Connection diameter: 3⁄4" npt
Assembly type: drooping type
K factor: 16.8 (242)
Certification: FM, UL, ULC, LPCB, VdS
Temperature: 74 ° C, 96 ° C
Surface: brass
Product Name: VK503
- ESFR (early suppression, fast response) in fire mode
- Use solder to withstand heat
- Protective shelf system
- Suitable for racking systems
- ESFR K that can be used in place of low pressure: 14

 
ESFR – K: 22.4 (320) sprinkler
Connection diameter: 1" npt
Assembly type: drooping type
K factor: 22.4 (320)
Certification: FM, UL, ULC, LPCB, VdS
Temperature: 74 ° C, 96 ° C
Surface: brass
Product Name: VK506
- ESFR (early suppression, fast response) in fire mode
- Use solder to withstand heat
- Protective shelf system
- Suitable for racking systems
- ESFR K that can be used in place of low pressure: 17

 
ESFR – K:25 (363) 噴淋頭
連接直徑:1”npt
裝配類型:下垂型
K因子:25 (363)
認(rèn)證:FM, UL, ULC, LPCB, VdS
溫度:74°C, 96°C
表面:黃銅
產(chǎn)品名稱:VK510
- 消防模式下的ESFR(早期抑制、快速響應(yīng))
- 使用焊料可耐強(qiáng)熱
- 保護(hù)貨架系統(tǒng)
- 適用于貨架系統(tǒng)
- 可代替低壓下工作的ESFR K:22
 

 
CMSA (控制模式特定應(yīng)用)灑水噴頭
高危環(huán)境® 大水滴
直立型灑水噴頭 K:11.2 (160)
連接直徑:½”npt – ¾”npt
裝配類型:直立型
K因子:11.2 (160)
認(rèn)證:FM, UL, ULC
溫度:68°C, 93°C, 141°C
表面:黃銅
產(chǎn)品名稱:VK540
-采用5 mm燈泡玻璃,耐高溫。
-設(shè)計(jì)用于高危環(huán)境®大水滴型灑水噴頭組A塑料消防噴淋管道??杀Wo(hù)高7.6 m和9.1 m的貨架系統(tǒng),而無需額外噴淋頭。
-貨架頂部的導(dǎo)流板和托盤間距必須至少為914 mm。
 

 
Standard response CMSA sprinkler
Sprinkler K:19.6 (282.6)
Connection diameter: 1" npt
Assembly type: drooping type
K factor: 19.6 (282.6)
Certification: FM, UL, ULC
Temperature: 71 ° C, 96 ° C
Surface: brass
Product Name: VK592
- Use solder to withstand heat.
- Designed for standard response CMSA sprinkler type sprinkler set A plastic fire sprinkler pipe. Protects rack systems up to 7.6 m and 9.1 m without the need for additional sprinklers.
- The baffle and pallet spacing at the top of the rack must be at least 914 mm.

 
CMDA (Control Mode Density Zone) Sprinkler
Upright sprinkler (storage density / area) K: 16.8 (242)
Connection diameter: 3⁄4" npt
Assembly type: upright type
K factor: 16.8 (242)
Certification: FM, UL, ULC
Temperature: 68 ° C, 79 ° C, 93 ° C, 141 ° C
Surface: brass
Product Name: VK580
- 5 mm bulb glass for high temperature resistance;
- With low pressure lines and low pressure pumps, it can be used in low pressure environments while saving some costs;
- Designed for high storage systems;
- Standard responsive sprinkler system.

 
ELO sr upright/sagging sprinkler
(Storage - Density / Area) K: 11.2 (160)
Connection diameter: 3⁄4" npt
Assembly type: upright type / drooping type
K factor: 11.2 (160)
Certification: FM, UL, ULC
Temperature: 68 ° C, 79 ° C, 93 ° C, 141 ° C
Surface: brass, chrome, black and white
Product Name: VK530 / VK536
- 5 mm bulb glass for high temperature resistance;
- standard responsive sprinklers;
- With large spray aperture, designed for high capacity storage and manufacturing;
- With low pressure pipeline and low pressure pump, it is suitable for low pressure environment while saving cost;
- Can be used as a medium-sized sprinkler if used with a sprinkler cover.

 
ELO qr upright / drooping sprinkler
(Storage - Density / Area) K: 11.2 (160)
Connection diameter: 3⁄4" npt
Assembly type: upright type / drooping type
K factor: 11.2 (160)
Certification: FM, UL, ULC
Temperature: 68 ° C, 79 ° C, 93 ° C, 141 ° C
Surface: brass, chrome, black and white
Product Name: VK531-533 / VK377
- High temperature resistance with 3 mm bulb glass and solder;
- a quick response sprinkler;
- With large spray aperture, designed for high capacity storage and manufacturing;
- With low pressure pipeline and low pressure pump, it is suitable for low pressure environment while saving cost;
- Can be used as a medium-sized sprinkler if used with a sprinkler cover.
EC storage (extended coverage) sprinkler
Extended Cover Upright Sprinkler (Storage - Density / Zone) K: 25.2 (363)
Connection diameter: 1⁄2" npt
Assembly type: upright type
K factor: 25.2 (363)
Certification: FM, UL, ULC
Temperature: 74 ° C, 101 ° C
Surface: brass
Product Name: VK595
- use solder to withstand strong heat;
- Designed for high-risk warehouses and production;
- The baffle and pallet spacing at the top of the rack must be at least 914 mm.
   

Product manual